Aliasing with data sampling
Aliasing with data sampling
This is very familiar to control engineers. Put in very simple language we have a particular print interval and this means we are sampling the results of the system at a particular frequency. If there is a phenomenon occurring in the results with another frequency, in order to see this phenomenon we must have a sampling frequency which is significantly higher.
In our example, the results are sampled every 0.1 s or at 10 Hz.
Procedure
- Plot the rotary speed of system B.
Figure 104: Rotary speed of system B
You see that the shaft is turning at 600 rev/min at the end of the simulation. This corresponds to 600/60 = 10 Hz. The data has been rather artificially created so that the print interval frequency coincides with the frequency of rotation.
- Try altering the constant torque to 610 Nm and to 590 Nm.
We still cannot properly see the phenomenon we are looking for: the output of the modulo block. To get a meaningful graph, we should sample at a significantly higher frequency than is contained in the data you are plotting.
- Try changing the print interval to 0.01 s (corresponding to 100 Hz) and to 0.001 s (1000 Hz).
An alternative is to select Discontinuity printout in the Run parameters dialog box.